Double LPG Filling Kit 1/2" UNF - W21,8 Filling Point with 4m LPG pipe and connectors

2VULSET4MUNF

LPG Filling set with 4m pipe to fill up with LPG 2x gas tank or gas bottles with 1/2" UNF Flare connection

LPG-Pipe:
Brand: LPG FIT
Manufacturer code: LPG-XD-5
Approval: E4 67R-010247
Inner diameter: Ø8mm
Outer diameter: Ø12.3mm
Pressure class: 67R-01 Class 1 (max. 30 bar)

LPG filling connection:
Approval : E13 67R-010077
Coupling & Thread: W21,8mm
Output Connection: 1/2"UNF - 3/4"-16 SAE 45°Flare Male (19mm) Angled
Input Connection: W21,8mm Internal
Material: Brass
Pressure class: 67R-01 Class 3 (max. 30 bar)

CHOOSE YOUR FILLING ADAPTER

€70.21 tax incl.
€82.60
Save 15%

Foreign companies with a valid VAT number shop VAT-free here! READ HOW.

- Delivery: 1-4 days
Option
Quantity
IN STOCK
  Safe Webshop

Webshop Trustmark & Secured by SSL. Your data and orders are safe here.

  Delivery policy

Safe and Secure Shipping with DPD or DHL

  Refund policy

Política de reembolso de 14 días y derecho de devolución

Double LPG Filling Kit 1/2" UNF - W21,8 Filling Point with 4m LPG pipe and connectors for 2x LPG-Tanks or 2x Gas Bottles

For filling 2x LPG gas tank or 2x Gas bottle with a coupling for a 80% fill stop (1/2" UNF). Ideal for in your car, camper or caravan. LPG pipe length to be used up to a maximum of 4 meters (to be shortened as desired).

This filling set with outer filler can be connected to 2x gas tanks with a 80% fill stop with a 3/4 UNF connection, so that you can safely fill your gas bottles. (Only use gas bottles with 80% fill protection).

The filling connection (W21,8 Filler) is standard equipped with the supplied Bayonet filling nipple. This allows you to fill in the Netherlands / UK. You can connect optional foreign filler nipples with W21.8 thread to the flat filler.

Complete set consisting of:
- 1 x Filling connection Type W21,8 Angular 1/2" UNF Outlet
- 3 x Straight Couplings for LPG pipe 1/2" UNF to connect to 80% fil stop and filling point
- 4 meter Thermoplastic pipe type XD-5 (can be shortened)
- 1 x T-junction to split the pipe to both gas tanks / bootles
- 5 x Pipe bracket for fixing the pipe
- 6 x Ortiker hoel clamp 
- Optional: Filling adapter (Bayonet, ACME, DISH, EURO-Connector or All Countries)

Advantages of the universal outdoor filling set:
- Very universally applicable and therefore always suitable for your camper or caravan
- More than sufficient pipe length that can be shortened as desired
- Filling connection recessed into sheet metal or under the vehicle using the supplied bracket
- Very high quality thanks to Automotive ECE 67R-01 certification
- Easy to install
- Complete with pipe brackets to fix everything neatly

Refillling Gas Bottles:
NB! Please note that in some countries (Italy and a number of Eastern European countries) refueling with LPG is not permitted. This may only be done by the pump station staff. Find out about the regulations of each country where you want to refuel.

Where can I refill my Gas Bottle? For example in the Netherlands, gas bottles may not be filled directly onto the bottle at the pump.

A gas bottle must be equipped with an 80% filling limiter, be properly secured in the vehicle and have an external filling connection.
Filling may be only permitted at and by authorized filling stations. This depends on national regulations.

Filling instructions:
1. Turn off the gas outlet (manual tap).
2. Make sure that the filling pipe with external filling connection or filling adapter is connected leak-free. (If necessary, use a filling adapter abroad)
3. Connect the filling nozzle to the filling connection.
4. Fill the gas bottle with the desired amount (maximum 80%)
5. Disconnect the filling nozzle and the filling pipe / filling coupling. (Be careful! Some LPG may be released)
6. Open the gas bottle tap again after refueling and before use.

General safety advice for LPG:
- Always keep the gas bottle upright.
- Do not drop the gas bottle from your vehicle as it may damage the bottle or the couplings.
- Do not store the gas bottle in the vicinity of an open flame.
- Do not use or store below ground level. Leaked gas will accumulate at a low level.
- The storage must be well ventilated, preferably outside.
- Do not use any tools to open the tap.
- Check the hoses regularly and see if the cylinder is properly secured. If the hoses are damaged or show signs of wear, replace the hoses (use the correct quality hoses).

Note: Filling may be only permitted at and by authorized filling stations.

2VULSET4MUNF

Data sheet

Attention!
It is mandatory to have this product installed by an expert. Our company disclaims all liability in the event of an accident.
Right of Withdrawal
The right of return expires when the transparent packaging is opened.
Downloads:
Manuals and Documentation - See the tab Attachments on this page.
Related Products:
See bottom of this page
Shipping Cost:
Is calculated in the Checkout and is visible there. (Depends on total weight, destination and discounts.)